- Centrifuge Tubes[1]
- Laboratory Centrifuge[10]
- Laboratory Heating Equipments[2]
- Laboratory Thermostatic Devices[6]
- Other Lab Supplies[6]
- Petri Dish[1]
- Test Tube[1]
- Other Electrical Equipment[1]
- Water Treatment[2]
- Hospital Cabinets[5]
- Laboratory Furniture[10]
- Filing Cabinets[2]
- Clinical Analytical Instruments[6]
- Dental Equipments[5]
- Medical Consumables[5]
- Sterilization Equipments[6]
- Ultrasonic Cleaners[6]
- Drying Equipment[5]
- Mixing Equipment[10]
- Other Chemical Equipment[3]
- Other Analysis Instruments[7]
- PH Meters[9]
- Instrument Parts & Accessories[2]
- Other Optics Instruments[4]
- Spectrometers[6]
- Temperature Instruments[2]
- Testing Equipment[10]
- Weighing Scales[6]
- Educational Equipment[2]
- Contact Person : Mr. Zhang Jimmy
- Company Name : Shanghai Lorderan Scientific Instrument Co., Ltd.
- Tel : 86-21-51159001, 60891036
- Fax : 86-21-60891036
- Address : Shanghai,Shanghai,Room 133, Section C, Bldg. 8, No. 152, Xiaodong Street, Jiading Industrial Zone
- Country/Region : China
- Zip : 201318
Related Product Searches:Flame/Graphite Furnace Atomic Absorption Spectrophotometer,High Quality,Flame Atomic Absorption Spectrophotometer, automatic spectrophotometer,WFX-210
1 Innovated rich oxygen air-acetylene flame analysis technique;
The patented flame analysis technique adopting rich oxygen air-acetylene flame as the substitution for nitrous oxide-acetylene flame for high temperature element analyses, such as Ca, Al, Ba, W, Mo, Ti, V, etc. Flame temeperature is continuously adjustable between 2300-2950 with makes it possible to choose the best atomization temperature for different elements. It features easy operation, low analysis cost and wide flame AAS analytical range. Rich oxygen flame will not pollute the environment and is not harmful to human bodies. It's break-through in flame AAS analysis
2 Integrated flame/graphite furnace atomization system, changeable with flame emission burner;
2.1 Automatically controlled changeover of the integrated flame and graphite furnace atomizer featuring easy operation and time saving eliminates human labor
2.2 A flame emission burner head can be installed to perform flame emission analysis to akali metais as K, Na etc.
3 Accurate fully automated control system
3.1 Automatic 6-lamp turret, automatic adjustment of lamp current and optimization of light beam position
3.2 Automatic wavelength scanning and peak picking
3.3 Automatic spectral bandwidth changing
3.4 Automatic changeover between flame and graphite furnace operation, automatic optimization of position parameters, automatic ignition and automatic gas flow setting
4 Reliable fully automatic graphite furnace analysis
4.1 Adopting FUZZY-PID and dual curve mode light-controlled temperature control technique, temperature auto-correction technique, ensures fast heating, good temperature reproducibility and high analytical sensitivity. The temperature control accuracy is less than 1%
4.2 Graphite furnace with pneumatic control and pressure lock ensures constant pressure and reliable contact
4.3 Multi-function autosampler features automatic standard sample preparation, automatic correction of sampling probe depth, automatic tracing and correction of liquid surface height in the sample vessel, with the sampling accuracy of 1% and reproducibility of 0.3%, realizing fully automation of graphite furnace analysis
Main Specification | Wavelength range | 190-900nm |
Wavelength accuracy | Better than ±0.25nm | |
Resolution | Two spectral lines of Mn at 279.5nm and 279.8nm can be separated with the spectral bandwidth of 0.2nm and valley-peak energy ratio less than 30%. | |
Baseline stability | 0.004A/30min | |
Background correction | The D2 lamp background correction capability at 1A is better than 30 times | |
The S-H background correction capability at 1.8A is better than 30 times. | ||
Light Source System | Lamp turret | Motorized 6-lamp turret ( Two high performance HCLs can be mounted on the turret to increase the sensitivity in flame analysis.); |
Lamp current adjustment | Wide pulse current: 0~25mA, | |
Narrow pulse current: 0~10mA | ||
Lamp power supply mode | 400Hz square wave pulse; | |
100Hz narrow square wave pulse+400Hz wide square wave pulse |
Flame/Graphite Furnace Atomic Absorption Spectrophotometer